                 Series SY 
                  100 - 1600 Gallons/Day (0.4 to 6m3/Day)                 
                
                Standar Equipment 
                
                  -   Thin film composite membranes
 
                  - FRP membrane housing
 
                  - Nickel-Aluminum-Bronze high pressure pumps
 
                  - Permeate and concentrate flow meters
 
                  - Low and high pressure safeguards
 
                  - Compact frame, with powder coated finish
 
                  - Automatic operation with level controls
 
                  - Stainless steel back pressure control
 
                  - 5 micron sediment filter and housing
 
                  - High pressure relief valve
 
                  - Auto feed shut-off (floats not included)
 
                  - Liquid filled system pressure gauge
 
                  - ROC-75 microprocessor controler with
				      
				        - Illuminated switches: auto operation, power/reset, manual
 
				        - Pretreatment lock-out
 
				        - Indicator lights: tank full (with RO shutdown), high pressure, pump on, low pressure, backwash
 
			           
                     
                   
                
                Optional Equipment 
                
                  -  TDS meter
 
                  - Antiscalant injection
 
                  - Sodium bisulfite injection
 
                  - Stainless steel high pressure pump
 
                  - Pulsation dampener
 
                  - Crating
 
                  - Pressure relief valve
 
                  - Hour meter
 
                  - Filter In/Out pressure gauges
 
                  - Multimedia filter
 
                  - Ultraviolet sterilizer (316 SS)
 
                   
                
                  
                    | Model | 
                    Capacity | 
                    Elements 
                      (2.5 diameter) | 
                    Line sizes In/cm  | 
                    Dimensions In/cm  | 
                    Wt lb/kg  | 
                    Motor HP  
                      (3-Phase) | 
                     
                  
                    | GPD | 
                    m3/day | 
                    Qty. | 
                    Length 
                      In/cm | 
                    Inlet | 
                    Perm | 
                    Conc | 
                    Lenght | 
                    Width | 
                    Height | 
                    60Hz 
                      110v | 
                    50Hz 
                      220v | 
                   
                  
                    | SY-12514CT | 
                    100 | 
                    0.4 | 
                    1 | 
                    14/36 | 
                    0.75 | 
                    0.375 | 
                    0.375 | 
                    36/91 | 
                    19/48 | 
                    17/43 | 
                    100/45 | 
                    1.5 | 
                    1.5 | 
                   
                  
                    | SY-22514CT | 
                    200 | 
                    0.8 | 
                    2 | 
                    14/36 | 
                    0.75 | 
                    0.375 | 
                    0.375 | 
                    36/91 | 
                    19/48 | 
                    17/43 | 
                    110/55 | 
                    1.5 | 
                    1.5 | 
                   
                  
                    | SY-22521CT | 
                    300 | 
                    1.1 | 
                    2 | 
                    14/36 | 
                    0.75 | 
                    0.375 | 
                    0.375 | 
                    36/91 | 
                    19/48 | 
                    17/43 | 
                    110/55 | 
                    1.5 | 
                    1.5 | 
                   
                  
                    | SY-12540CT | 
                    400 | 
                    1.5 | 
                    1 | 
                    40/102 | 
                    0.75 | 
                    0.375 | 
                    0.375 | 
                    54/137 | 
                    19/48 | 
                    17/43 | 
                    130/60 | 
                    1.5 | 
                    1.5 | 
                   
                  
                    | SY-22540CT | 
                    800 | 
                    3.0 | 
                    2 | 
                    40/102 | 
                    0.75 | 
                    0.375 | 
                    0.375 | 
                    54/137 | 
                    19/48 | 
                    17/43 | 
                    140/65 | 
                    2.0  | 
                    2.0 | 
                   
                  
                    | SY-32540CT | 
                    1200 | 
                    4.5 | 
                    3 | 
                    40/102 | 
                    0.75 | 
                    0.375 | 
                    0.375 | 
                    54/137 | 
                    19/48 | 
                    17/43 | 
                    150/70 | 
                    2.0 | 
                    2.0 | 
                   
                  
                    | SY-42540CT | 
                    1600 | 
                    6.0 | 
                    4 | 
                    40/102 | 
                    0.75 | 
                    0.375 | 
                    0.375 | 
                    54/137 | 
                    19/48 | 
                    17/43 | 
                    180/85 | 
                    2.0 | 
                    2.0 | 
                   
                 
                Notes 
                
                  - All dimensions and weights are approximate
 
                  - Based on 35,000 ppm seawater at 77°F (25°C). Recovery in the range of 10-15%
 
                  - Operating pressure 800-1000 psi (57-71 kg/cm2) 
 
                   
                Ordering Information 
                Please add our voltage codes to the end of the number when ordering. 
                  Example: SY-12514CT-236 = 220v/230v / 3ph / 60hz 
                
                  
                    | Voltage Code  | 
                    236=220 or 230v/ 3ph / 60hz  | 
                    235=220 / 3ph / 50hz | 
                   
                  
                    | Examples | 
                    436=460 or 480v/ 3ph / 60hz  | 
                    335=380 / 3ph / 50hz | 
                   
                 
                
                  
                    
                       
                      0.4 m3 x día  | 
                    
                       
                      0.7 m3 x día  | 
                     
                 
                
                  
                    
                       
                      12,000 galones x día  | 
                    
                       
                      60,000 galones x día  | 
                   
                 
                
                  
                     | 
                     
                  
                    
                         
                        Kit de bomba y motor de alta presion ( 1,200 psi) para desaladora de  
                      37 galones por minuto | 
                    
                         
                       Turbo especial para agua de mar,  se utiliza para diminuir en un 40% el tamaño del motor principal del osmosis inversa. En lugar de utilizar 1 motor de 1000 hp con este turbo se utilizaria un motor de 600 hp
                        | 
                   
                 
               |